BAC S15E 1018-10 LE উন্মুক্ত কুলিং টাওয়ারBAC
S1500E
BAC S15E 1018-10 LE উন্মুক্ত কুলিং টাওয়ার
BAC
S1500E
VB ট্যাক্স (মূসক) অতিরিক্ত
২৬,৮০০€
অবস্থা
ব্যবহৃত
অবস্থান
Borken 

মেশিন সংক্রান্ত তথ্য
মূল্য এবং অবস্থান
VB ট্যাক্স (মূসক) অতিরিক্ত
২৬,৮০০€
- অবস্থান:
- 46325 Borken, Deutschland

কল করুন
প্রস্তাবের বিবরণ
- বিজ্ঞাপন আইডি:
- A21340202
- রেফারেন্স নম্বর:
- 60821
- আপডেট:
- সর্বশেষ ০২.০৬.২০২৬
বিবরণ
BAC S1500E Cooling Tower
The BAC S15E 1018-10-LE is a high-performance open cooling tower from the S1500E series by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are top priorities.
Technology
Patented BACross III fill system, which allows for easy inspection of the fill sheets to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance Access: A large, inward-swinging access door and internal maintenance platforms allow technicians to comfortably perform inspections while standing inside the unit.
Hygiene Control: The design minimizes stagnant water and, thanks to special air inlet louvers, provides protection against sunlight, thereby reducing algae growth.
Flexibility: Due to the single-sided air inlet, the cooling tower can be installed even in confined spaces or positioned directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial Cooling: Used in factories for process cooling.
HVAC: Deployed in large building complexes as part of the central cooling plant.
Kdodpfoynkbmex Al Uen
Refrigeration: Serves as a condenser in commercial refrigeration circuits.
Cooling Capacity
An open evaporative cooling tower does not possess a single, fixed kW cooling capacity, as the actual performance depends entirely on thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second. Under typical industrial or standard HVAC conditions, the nominal cooling capacity of this model ranges from approximately 1,200 kW to 2,100 kW.
Why does cooling capacity vary?
Wet-bulb temperature (ambient air): The cooler and drier the ambient air, the more water can evaporate, resulting in a higher cooling capacity.
Water temperatures: Performance varies significantly depending on the incoming hot water temperature (e.g., 35 °C) and the outgoing cold water temperature (e.g., 29 °C).
Air volume flow: According to BAC’s technical specifications, the S15E 1018-10 LE model actively moves 60.0 m³/s of air using three installed 11.0 kW fan motors.
If this airflow volume is reduced via a variable frequency drive (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This represents the most critical thermodynamic limit. It describes the temperature difference between the desired cold water temperature and the prevailing wet-bulb temperature. The closer the cold water is required to be cooled to the wet-bulb temperature (i.e., a smaller approach), the lower the cooling capacity the tower can deliver. Technical Specifications:
Fan & Air Data
Airflow Rate: 60.0 m³/s (generated in suction mode)
Fan Motors: 3x 11.0 kW (Axial fans)
Technology: Integrated belt drive
Water Flow Rate: 198 l/s
Hydraulic Connections
Water Inlet (Fluid Inlet): 1x DN 250 (Nominal Diameter ND 250 mm)
Water Outlet (Fluid Outlet): 1x DN 300 (Nominal Diameter ND 300 mm)
Fresh Water Connection (Make-up): 1x DN 40 (ND 40 mm)
Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
The BAC S15E 1018-10-LE is a high-performance open cooling tower from the S1500E series by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are top priorities.
Technology
Patented BACross III fill system, which allows for easy inspection of the fill sheets to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance Access: A large, inward-swinging access door and internal maintenance platforms allow technicians to comfortably perform inspections while standing inside the unit.
Hygiene Control: The design minimizes stagnant water and, thanks to special air inlet louvers, provides protection against sunlight, thereby reducing algae growth.
Flexibility: Due to the single-sided air inlet, the cooling tower can be installed even in confined spaces or positioned directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial Cooling: Used in factories for process cooling.
HVAC: Deployed in large building complexes as part of the central cooling plant.
Kdodpfoynkbmex Al Uen
Refrigeration: Serves as a condenser in commercial refrigeration circuits.
Cooling Capacity
An open evaporative cooling tower does not possess a single, fixed kW cooling capacity, as the actual performance depends entirely on thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second. Under typical industrial or standard HVAC conditions, the nominal cooling capacity of this model ranges from approximately 1,200 kW to 2,100 kW.
Why does cooling capacity vary?
Wet-bulb temperature (ambient air): The cooler and drier the ambient air, the more water can evaporate, resulting in a higher cooling capacity.
Water temperatures: Performance varies significantly depending on the incoming hot water temperature (e.g., 35 °C) and the outgoing cold water temperature (e.g., 29 °C).
Air volume flow: According to BAC’s technical specifications, the S15E 1018-10 LE model actively moves 60.0 m³/s of air using three installed 11.0 kW fan motors.
If this airflow volume is reduced via a variable frequency drive (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This represents the most critical thermodynamic limit. It describes the temperature difference between the desired cold water temperature and the prevailing wet-bulb temperature. The closer the cold water is required to be cooled to the wet-bulb temperature (i.e., a smaller approach), the lower the cooling capacity the tower can deliver. Technical Specifications:
Fan & Air Data
Airflow Rate: 60.0 m³/s (generated in suction mode)
Fan Motors: 3x 11.0 kW (Axial fans)
Technology: Integrated belt drive
Water Flow Rate: 198 l/s
Hydraulic Connections
Water Inlet (Fluid Inlet): 1x DN 250 (Nominal Diameter ND 250 mm)
Water Outlet (Fluid Outlet): 1x DN 300 (Nominal Diameter ND 300 mm)
Fresh Water Connection (Make-up): 1x DN 40 (ND 40 mm)
Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
যোগানদাতা
বিঃদ্রঃ বিনামূল্যে নিবন্ধন করুন বা লগইন করুন, সমস্ত তথ্য পেতে।
সর্বশেষ অনলাইনে: গতকাল
থেকে নিবন্ধিত: 2008
৫৬১ অনলাইন বিজ্ঞাপন
অনুরোধ পাঠান
টেলিফোন & ফ্যাক্স
+49 2862 ... বিজ্ঞাপন
এই বিজ্ঞাপনগুলি আপনারও আগ্রহের হতে পারে।
ক্ষুদ্র বিজ্ঞাপন
Altomünster
৭,২৯০ km
রিটার্ন কুলার, ফ্রি কুলার, টেবিল কুলার
Güntner, Cabero, GEA, Thermokey,Güntner , Jäggi, Cabero, GEA
Güntner, Cabero, GEA, Thermokey,Güntner , Jäggi, Cabero, GEA
ক্ষুদ্র বিজ্ঞাপন
Łęczna
৬,৪৩৭ km
চিলার/তাপ পাম্প
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
ক্ষুদ্র বিজ্ঞাপন
Niedźwiedź
৬,৬৩৪ km
কম্প্রেসার ইউনিট
BITZER4NCS-12.2Y-40-40P (x4)
BITZER4NCS-12.2Y-40-40P (x4)
ক্ষুদ্র বিজ্ঞাপন
Niedźwiedź
৬,৬৩৪ km
কনডেন্সার
GüntnerGVH 090.2A/2x5-N(D)
GüntnerGVH 090.2A/2x5-N(D)
ক্ষুদ্র বিজ্ঞাপন
রোমানিয়া
৭,৫২০ km
Engel DUO 3550/400 পিকো
EngelDUO 3550/400 pico
EngelDUO 3550/400 pico
ক্ষুদ্র বিজ্ঞাপন
Hillegom
৭,৬৭৭ km
ড্রাইকুলার
CaberoGCHSD089MB/X7S-40 Y V
CaberoGCHSD089MB/X7S-40 Y V
ক্ষুদ্র বিজ্ঞাপন
Lanaken
৭,৬৩৭ km
প্লেট তাপ এক্সচেঞ্জার
SondexSF160
SondexSF160
ক্ষুদ্র বিজ্ঞাপন
Enschede
৭,৫২০ km
ইনজেকশন ছাঁচনির্মাণ মেশিন
ENGELE-VICTORY 765H/170W/400 COMBI
ENGELE-VICTORY 765H/170W/400 COMBI
ক্ষুদ্র বিজ্ঞাপন
Niedźwiedź
৬,৬৩৪ km
শুকনো কুলার
CaberoS-GC/DED 095 KA/2X4E
CaberoS-GC/DED 095 KA/2X4E
ক্ষুদ্র বিজ্ঞাপন
Ecquevilly
৭,৯৪৫ km
কুলিং গ্রুপ
Copeland EmersonZXLE 50
Copeland EmersonZXLE 50
আপনার বিজ্ঞাপন সফলভাবে মুছে ফেলা হয়েছে
একটি ত্রুটি ঘটেছে

















































































